A Portable, Neurostimulation-Integrated, Force Measurement Platform for the Clinical Assessment of Plantarflexor Central Drive

Autor: Ashley N. Collimore, Jonathan T. Alvarez, David A. Sherman, Lucas F. Gerez, Noah Barrow, Dabin K. Choe, Stuart Binder-Macleod, Conor J. Walsh, Louis N. Awad
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Bioengineering, Vol 11, Iss 2, p 137 (2024)
Druh dokumentu: article
ISSN: 2306-5354
DOI: 10.3390/bioengineering11020137
Popis: Plantarflexor central drive is a promising biomarker of neuromotor impairment; however, routine clinical assessment is hindered by the unavailability of force measurement systems with integrated neurostimulation capabilities. In this study, we evaluate the accuracy of a portable, neurostimulation-integrated, plantarflexor force measurement system we developed to facilitate the assessment of plantarflexor neuromotor function in clinical settings. Two experiments were conducted with the Central Drive System (CEDRS). To evaluate accuracy, experiment #1 included 16 neurotypical adults and used intra-class correlation (ICC2,1) to test agreement of plantarflexor strength capacity measured with CEDRS versus a stationary dynamometer. To evaluate validity, experiment #2 added 26 individuals with post-stroke hemiparesis and used one-way ANOVAs to test for between-limb differences in CEDRS’ measurements of plantarflexor neuromotor function, comparing neurotypical, non-paretic, and paretic limb measurements. The association between paretic plantarflexor neuromotor function and walking function outcomes derived from the six-minute walk test (6MWT) were also evaluated. CEDRS’ measurements of plantarflexor neuromotor function showed high agreement with measurements made by the stationary dynamometer (ICC = 0.83, p < 0.001). CEDRS’ measurements also showed the expected between-limb differences (p’s < 0.001) in maximum voluntary strength (Neurotypical: 76.21 ± 13.84 ft-lbs., Non-paretic: 56.93 ± 17.75 ft-lbs., and Paretic: 31.51 ± 14.08 ft-lbs.), strength capacity (Neurotypical: 76.47 ± 13.59 ft-lbs., Non-paretic: 64.08 ± 14.50 ft-lbs., and Paretic: 44.55 ± 14.23 ft-lbs.), and central drive (Neurotypical: 88.73 ± 1.71%, Non-paretic: 73.66% ± 17.74%, and Paretic: 52.04% ± 20.22%). CEDRS-measured plantarflexor central drive was moderately correlated with 6MWT total distance (r = 0.69, p < 0.001) and distance-induced changes in speed (r = 0.61, p = 0.002). CEDRS is a clinician-operated, portable, neurostimulation-integrated force measurement platform that produces accurate measurements of plantarflexor neuromotor function that are associated with post-stroke walking ability.
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje