Inoculum Size and False-Positive Detection of NDM- and OXA-48-Type Carbapenemases Using Two Multiplex Lateral Flow Assays

Autor: Chung-Ho Lee, Huiluo Cao, Shuo Jiang, Tammy Ting-Yan Wong, Cindy Wing-Sze Tse, Pak-Leung Ho
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Diagnostics, Vol 14, Iss 12, p 1274 (2024)
Druh dokumentu: article
ISSN: 2075-4418
DOI: 10.3390/diagnostics14121274
Popis: The NG-Test CARBA 5 and Carbapenem-resistant K.N.I.V.O. Detection K-Set are lateral flow assays (LFAs) that rapidly detect five carbapenemases (KPC, NDM, IMP, VIM and OXA-48-like). We evaluated the effect of inoculum size on the performance of these two assays using 27 Enterobacterales isolates. Whole-genome sequencing (WGS) was used as the reference method. Using the NG-Test CARBA 5, eight Serratia spp. and six M. morganii isolates showed false-positive NDM results with a high inoculum. Using the Carbapenem-resistant K.N.I.V.O. Detection K-Set, eight M. morganii, four Serratia spp. and one K. pneumoniae isolates showed false-positive NDM and/or OXA-48-like bands at large inoculum sizes, while the other two M. morganii isolates demonstrated false-positive NDM and OXA-48-like results at all inoculum sizes. The false-positive bands varied in intensity. WGS confirmed that no carbapenemase gene was present. No protein sequence with a ≥50% identity to NDM or OXA-48-like enzymes was found. This study emphasizes the importance of assessing inoculum size in the diagnostic evaluation of LFAs.
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje