Phototherapy Using a Light-Emitting Fabric (BUBOLight) Device in the Treatment of Newborn Jaundice: Protocol for an Interventional Feasibility and Safety Study

Autor: Lecomte, Fabienne, Thecua, Elise, Ziane, Laurine, Deleporte, Pascal, Duhamel, Alain, Vamour, Clémence, Mordon, Serge, Rakza, Thameur
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: JMIR Research Protocols, Vol 10, Iss 5, p e24808 (2021)
Druh dokumentu: article
ISSN: 1929-0748
DOI: 10.2196/24808
Popis: BackgroundNeonatal jaundice is a common condition occurring in 60%-80% of all healthy-term and late-preterm neonates. In the majority of cases, neonatal jaundice resolves spontaneously and causes no harm; however, in some neonates, significant hyperbilirubinemia can develop and lead to kernicterus jaundice, a serious neurological disease. Phototherapy (PT) is the preferred treatment for jaundice; however, to be effective, PT devices need to have a broad light emission surface to generate no or little heat and to provide an optimal wavelength and light intensity (420-490 nm and ≥30 µW/cm²/nm, respectively). ObjectiveThis study aimed to investigate the feasibility, safety, and level of satisfaction of parents and health care teams with the BUBOlight device, an innovative alternative to conventional hospital PT, in which luminous textiles have been incorporated in a sleeping bag. MethodsThis interventional, exploratory, simple group, nonrandomized, single-center trial will be conducted at Lille Hospital. In total, 10-15 neonates and their parents will be included to obtain evaluable data from 10 parent-neonate pairs. Neonates weighing more than 2500 g at birth and born with ≥37 weeks of amenorrhea that required PT in accordance with the guidelines of the National Institute For Health and Clinical Excellence will receive one 4-hour session of illumination. Total serum bilirubin and transcutaneous bilirubin levels were obtained at the start and 2 hours after the end of PT. Cutaneous and rectal temperatures, heart rate, and oxygen saturation will be measured at the beginning and during PT. The number of subjects is therefore not calculated on the basis of statistical assumptions. We aim to obtain a minimum proportion of 90% (ie, 9 of 10) of the neonates included, who have been able to undergo 4-hour PT without unacceptable and unexpected toxicities. We will calculate the mean, median, quartiles, minimum and maximum values of the quantitative parameters, and the frequency of the qualitative parameters. The rate of patients with no unacceptable and unexpected toxicities (ie, the primary endpoint) will be calculated. ResultsThe first patient is expected to be enrolled at the end of 2020, and clinical investigations are intended for up to June 2021. The final results of this study are expected to be available at the end of 2021. ConclusionsOur findings will provide insights into the safety and feasibility of a new PT device based on light-emitting fabrics for the treatment of newborn jaundice. This new system, if proven effective, will improve the humanization of neonatal care and help avoid mother-child separation. Trial RegistrationClinicalTrials.gov NCT04365998; https://clinicaltrials.gov/ct2/show/NCT04365998 International Registered Report Identifier (IRRID)PRR1-10.2196/24808
Databáze: Directory of Open Access Journals