Orbital Gas after 25-Gauge Pars Plana Vitrectomy with Incorrect Gas Mixture

Autor: Noy Ashkenazy, Carl J. Danzig, Andrew J. Rong, Sarah P. Read, Michelle M. Maeng, Harry W. Flynn Jr., Thomas A. Albini
Jazyk: angličtina
Rok vydání: 2023
Předmět:
Zdroj: Case Reports in Ophthalmology, Vol 14, Iss 1, Pp 301-306 (2023)
Druh dokumentu: article
ISSN: 1663-2699
DOI: 10.1159/000530401
Popis: We present 2 cases of sutureless 25-gauge pars plana vitrectomy and fluid-gas exchange, in which incorrect gas concentrations likely led to elevated intraocular pressures and retrobulbar gas. Combined removal of orbital gas with anterior orbitotomy and pars plana vitrectomy was performed in the first case to address expanding intraocular and retrobulbar gas resulting from a suspected error in gas dilution. Vitreous and orbital gas removal by needling was effective in the second case. In patients with elevated intraocular pressure and orbital gas accumulation after vitrectomy, combined intraocular and orbital decompressions were effective in optimizing clinical outcomes. There is no consensus regarding the best management of orbital gas after vitrectomy. We propose that a multidisciplinary technique should be considered, when available.
Databáze: Directory of Open Access Journals