Correcting motion induced fluorescence artifacts in two-channel neural imaging.
Autor: | Matthew S Creamer, Kevin S Chen, Andrew M Leifer, Jonathan W Pillow |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | PLoS Computational Biology, Vol 18, Iss 9, p e1010421 (2022) |
Druh dokumentu: | article |
ISSN: | 1553-734X 1553-7358 |
DOI: | 10.1371/journal.pcbi.1010421 |
Popis: | Imaging neural activity in a behaving animal presents unique challenges in part because motion from an animal's movement creates artifacts in fluorescence intensity time-series that are difficult to distinguish from neural signals of interest. One approach to mitigating these artifacts is to image two channels simultaneously: one that captures an activity-dependent fluorophore, such as GCaMP, and another that captures an activity-independent fluorophore such as RFP. Because the activity-independent channel contains the same motion artifacts as the activity-dependent channel, but no neural signals, the two together can be used to identify and remove the artifacts. However, existing approaches for this correction, such as taking the ratio of the two channels, do not account for channel-independent noise in the measured fluorescence. Here, we present Two-channel Motion Artifact Correction (TMAC), a method which seeks to remove artifacts by specifying a generative model of the two channel fluorescence that incorporates motion artifact, neural activity, and noise. We use Bayesian inference to infer latent neural activity under this model, thus reducing the motion artifact present in the measured fluorescence traces. We further present a novel method for evaluating ground-truth performance of motion correction algorithms by comparing the decodability of behavior from two types of neural recordings; a recording that had both an activity-dependent fluorophore and an activity-independent fluorophore (GCaMP and RFP) and a recording where both fluorophores were activity-independent (GFP and RFP). A successful motion correction method should decode behavior from the first type of recording, but not the second. We use this metric to systematically compare five models for removing motion artifacts from fluorescent time traces. We decode locomotion from a GCaMP expressing animal 20x more accurately on average than from control when using TMAC inferred activity and outperforms all other methods of motion correction tested, the best of which were ~8x more accurate than control. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |