Influence of irradiation distance on the mechanical performances of resin composites polymerized with high-irradiance light curing units

Autor: Soram Oh, Hyun Ju Kim, Hyun-Jung Kim, Sibel A. Antonson, Sun-Young Kim
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Biomaterials Research, Vol 26, Iss 1, Pp 1-11 (2022)
Druh dokumentu: article
ISSN: 2055-7124
DOI: 10.1186/s40824-022-00267-5
Popis: Abstract Background The aim of this study was to evaluate the influence of increased irradiation distance on the flexural strength (FS), dentin micro-shear bond strength (μSBS), and the degree of conversion (DC) of bulk-fill flowable, conventional flowable, and packable resin composites. Methods The resin composites tested were Surefil® SDR™ (SDR), Filtek Z350 XT Flowable Restorative A2 shade (Z3F), and Filtek Z350 XT Universal Restorative A2 shade (Z3P). Specimens were cured at four irradiation distances (0, 2, 4, and 8 mm) with an Elipar DeepCure-S LED curing light for 20 s. FS tests were performed (n = 15) using bar-shaped specimens (8 mm × 2 mm × 2 mm) of the resin composites. μSBS tests were performed on the occlusal surfaces of extracted third molars from humans that were ground to expose dentin (n = 15). DC was measured by using Raman spectroscopy on the top and bottom surfaces of disk specimens (2-mm thick) (n = 3). To further investigate whether extended irradiation times could compensate for reduced irradiance, additional Z3P specimens were prepared, which were light-cured at 8-mm distances for 40 and 60 s and subjected to FS tests, μSBS tests, and Raman spectroscopy. Both two-way and one-way ANOVA were used for statistical analyses. Results Both FS and DC of Z3P specimens cured at an 8-mm distance were significantly lower than those cured at shorter distances (p
Databáze: Directory of Open Access Journals