Popis: |
Purpose: Intraoral stents protect the healthy tissues from ionizing radiation during external beam radiotherapy reducing mucositis, hyposalivation and osteoradionecrosis. This study investigated the radiodensity and dimensional stability of polymeric materials for suitability in construction of intraoral stents and aimed to provide clinical guidelines. Methods: Specimens were fabricated using 4 material types namely, resin composite (ProTemp-PRO), polymethylmethacrylate (PMMA) (Enamel Temp Plus-ETP, Palapress-PAL, TAB 2000-TAB), polycaprolactone (Orfit-ORF) and silicone (Adisil-ADI, Lab Putty-LAB, Memosil2-MEM, Optosil-OPT, President Plus-PRE, Siolaplast A-SIA). They were randomly assigned to measure their radiodensity in Hounsfield Units (HU) (12x12x11mm3) (Nradiodensity = 66; n = 6) using a computer tomograph (CBCT, Toshiba Aquillon LB scanner) at baseline and after 6 weeks. The scanning protocol was applied with and without single energy metal artifact reduction (SEMAR) scans using a slice thickness of 1 and 5 mm. The same materials have been tested for their dimensional stability (µm3) at baseline, 1, 6, 12, 24 h, 3 and 6 weeks (14 × 4 × 2 mm3) (Ndimension = 55; n = 5 per material) using stereolithography (STL) files generated by a lab scanner (L2i, Imetric4D, Courgenay, Switzerland) and analyzed using a matching software (Geomagic ControlX 2020, 3D Systems). Data were analyzed using a paired t-test (alpha = 0.05). Results: Radiodensity values (HU) were significantly affected by the material classification (p |