In Vivo Disintegration of Four Different Luting Agents
Autor: | Deniz Gemalmaz, Cornelis H. Pameijer, Mark Latta, Ferah Kuybulu, Toros Alcan |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2012 |
Předmět: | |
Zdroj: | International Journal of Dentistry, Vol 2012 (2012) |
Druh dokumentu: | article |
ISSN: | 1687-8728 1687-8736 |
DOI: | 10.1155/2012/831508 |
Popis: | The purpose of this study was to evaluate the disintegration of luting agents. An intraoral sample holder was made having four holes of 1.4 mm diameter and 2 mm depth. The holder was soldered onto the buccal surface of an orthodontic band, which was cemented to the first upper molar in 12 patients, average age 26 years. The holes were filled with a zinc phosphate (Phosphate Kulzer), a glass ionomer (Ketac Cem), a resin-modified-glass ionomer (Fuji Plus), and a resin cement (Calibra). Impressions were made at baseline, and 6, 12, and 18 months from which epoxy replicas were made, which were scanned with an optical scanner. Total volume loss was calculated. The rank order of mean volume loss was as follows: Phosphate cement > Ketac Cem = Fuji Plus = Calibra. Cement type and time had statistically significant effects on volume loss of cements (P |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |