Popis: |
Abstract Background Neuromuscular electrical stimulation (NMES) may prevent muscle atrophy, accelerate rehabilitation and enhance blood circulation. Yet, one major drawback is that patient compliance is impeded by the discomfort experienced. It is well-known that the size and placement of electrodes affect the comfort and effect during high-intensity NMES. However, during low-intensity NMES the effects of electrode size/placement are mostly unknown. Therefore, the purpose of this study was to investigate how electrode size and pragmatic placement affect comfort and effect of low-intensity NMES in the thigh and gluteal muscles. Methods On 15 healthy participants, NMES-intensity (mA) was increased until visible muscle contraction, applied with three electrode sizes (2 × 2 cm, 5 × 5 cm, 5 × 9 cm), in three different configurations on quadriceps and hamstrings (short-transverse (ST), long-transverse (LT), longitudinal (L)) and two configurations on gluteus maximus (short-longitudinal (SL) and long-longitudinal (LL)). Current–density (mA/cm2) required for contraction was calculated for each electrode size. Comfort was assessed with a numerical rating scale (NRS, 0–10). Significance was set to p |