Reliability of qualitative occlusal tooth wear evaluation using an intraoral scanner: A pilot study.

Autor: Renata Travassos da Rosa Moreira Bastos, Priscila Teixeira da Silva, David Normando
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: PLoS ONE, Vol 16, Iss 3, p e0249119 (2021)
Druh dokumentu: article
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0249119
Popis: Dental wear analysis through the use of an intraoral scanner is a reality of modern dentistry. This study aimed to investigate the reliability of qualitative tooth wear evaluation through three-dimensional images captured with an intraoral scanner and compared to clinical and photographic examinations. Eighteen adult volunteers of both genders (18 to 55 years old) were submitted to clinical exams, intraoral photographs and intraoral scanning protocol using an optical scanner (TRIOS® Pod, 3Shape, Copenhagen, Denmark). Occlusal tooth wear, from second to second premolars, was measured by two evaluators and reevaluated after 30 days, according to a slight modification of the method described by Mockers et al. Weighted Kappa was used to measure intra and inter-examiner agreement. The Friedman test was used to verify the differences among methods. Random and systematic errors were assessed using Bland-Altman plots. All statistical analysis was performed with p