Intracameral Air and Fibrin Glue for the Management of Late Bleb Leak following Glaucoma Surgery

Autor: Mohammed R. Hayat, Fatema S. Mollah, Kamal Kishore
Jazyk: angličtina
Rok vydání: 2019
Předmět:
Zdroj: Case Reports in Ophthalmology, Vol 10, Iss 1, Pp 47-52 (2019)
Druh dokumentu: article
ISSN: 1663-2699
00049638
DOI: 10.1159/000496383
Popis: Background and Objectives: To report a case of delayed-onset bleb-associated endophthalmitis (BAE) with bleb leak successfully managed with pars plana vitrectomy, intravitreal antibiotics, intracameral air, and fibrin glue. Patient and Methods: A 66-year-old pseudophakic female presented with BAE and bleb leak. A 25-gauge pars plana vitrectomy, cultures, and intravitreal antibiotics and steroid injections were performed. The infusion was switched to air filling the anterior chamber and bleb with air. Fibrin glue (Tisseel®) was applied over the leaking bleb. Results: BAE and bleb leak resolved with return of visual acuity to 20/25 and a functioning bleb with no recurrence of bleb leak after 1 year of follow-up. Conclusion: The combination of intracameral air and fibrin glue may have a role in the management of bleb leaks.
Databáze: Directory of Open Access Journals