Corrosion protection failure test analysis of the initial damaged cable ICCP mechanism

Autor: Xuanbo He, Guowen Yao, Hong Long, Li Ying, Zengwei Guo, Ling Zhao, Yang Tang, Peiyan Huang
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Case Studies in Construction Materials, Vol 20, Iss , Pp e03227- (2024)
Druh dokumentu: article
ISSN: 2214-5095
DOI: 10.1016/j.cscm.2024.e03227
Popis: Given the corrosion protection failure of the cable-stayed bridge cable in the actual project, the impressed current cathodic protection (ICCP) technology was used to carry out the anti-corrosion tests from steel wire scale to cable scale, analyze the corrosion protection characteristics of steel wire ICCP, deduce the corrosion factor ICCP diffusion model, and reveal the space ICCP mechanism of the initial damaged cable. The analysis shows that ICCP can effectively inhibit the corrosive effect of steel wires and cables, and reduce the loss of mechanical properties of steel wires. Its protective efficiency increases with an increase in the absolute value of its protective potential and decreases with an increase in the dead load level. ICCP has a blocking effect on the diffusion of corrosion factors in the cable space, and the corrosion spatial distribution range, corrosion factor concentration, and diffusion coefficient of the initial damaged cable decrease significantly with the increase in the absolute value of the protection potential. The open circuit potential moves in a positive direction with the development of the corrosion process, and the blocking effect of corrosive factor diffusion is transformed from the joint participation by sacrificial anode cathodic protection and ICCP to the dominance of ICCP.
Databáze: Directory of Open Access Journals