Effect of long-term rotation on astigmatism following EVO-toric intraocular collamer lens implantation

Autor: Xun Chen, Huamao Miao, Mingrui Cheng, I-Chun Lin, Boliang Li, Yinjie Jiang, Yadi Lei, Xiaoying Wang, Xingtao Zhou
Jazyk: angličtina
Rok vydání: 2023
Předmět:
Zdroj: Frontiers in Medicine, Vol 10 (2023)
Druh dokumentu: article
ISSN: 2296-858X
DOI: 10.3389/fmed.2023.1194006
Popis: ObjectiveTo evaluate the effect of long-term rotation on astigmatism following Evolution-toric intraocular collamer lens (EVO-TICL) implantation.MethodsForty eyes of 22 patients were enrolled in this prospective study. Visual acuity, refractive parameters, and axial position of the EVO-TICL by OPD-Scan III aberrometer were measured preoperatively, 1 month and 3 years postoperatively.ResultsLast visit, the safety index was 1.32 ± 0.15 and the efficacy index was 1.01 ± 0.23. The best-fitting curve of the attempted versus achieved correction was y = 0.9751x + 0.001. The mean spherical equivalent (SE) decreased from −8.94 ± 2.72D preoperatively to 0.06 ± 0.24D and − 0.36 ± 0.46D 1 month and 3 years postoperatively, respectively. The mean target and surgical induced astigmatism were 1.55 ± 0.61D and 1.67 ± 0.94D 3 years postoperatively. The average expected axis of the TICL was-1.15 ± 9.07 (−21–19°). One month and 3 years postoperatively, the average actual axis was −0.70 ± 9.86 (−20–20°) and − 0.35 ± 11.72 (−25–30°), respectively. The absolute rotation of the TICL was 3.70 ± 4.42 (0–22°) and 6.00 ± 6.70 (0–32°) 1 month and 3 years postoperatively, respectively (p