A New Sutureless Illuminated Macular Buckle Designed for Myopic Macular Hole Retinal Detachment

Autor: Ahmed M. Bedda, Ahmed M. Abdel Hadi, Mohamed Lolah, Muhammad S. Abd Al Shafy
Jazyk: angličtina
Rok vydání: 2017
Předmět:
Zdroj: Journal of Ophthalmology, Vol 2017 (2017)
Druh dokumentu: article
ISSN: 2090-004X
2090-0058
DOI: 10.1155/2017/6742164
Popis: Purpose. To report the anatomic and visual results of a new sutureless illuminated macular buckle designed for patients with macular hole retinal detachment related to high myopia (MMHRD). Design. Prospective nonrandomized comparative interventional trial. Methods. Twenty myopic eyes of 20 patients (mean age, 51.4 years; range, 35–65 years) presenting with MMHRD with a posterior staphyloma, in whom the new buckle was used, were evaluated. The buckle used was assembled from a 5 mm wide sponge and a 7 mm wide silicone tire; it was fixed utilizing the sterile topical adhesive Histoacryl Blue (B Braun, TS1050044FP) which polymerizes in seconds upon being exposed to water-containing substances. The primary outcomes measured included aided visual acuity (BCVA) and optical coherence tomography (OCT) findings. The mean follow-up period was 6 months. Results. Postoperatively, the MH closure was identified by OCT in 8 (40%) eyes. The mean BCVA increased from 0.11 to 0.21 (p
Databáze: Directory of Open Access Journals