Abstract Purpose To explore the outcomes of bone augmentation in the aesthetic zone of the anterior teeth using computer-aided design and a 3D-printed template. Methods Ten patients with severe bone defects in the aesthetic zone of anterior teeth were included in the study; CT data were collected before surgery. The design of the osteotomy line in the bone defect area was determined under computer simulation. The position parameters and osteotomy line of the free bone were determined via virtual surgery. A 3D-printed template was prepared to guide the accurate placement of the bone graft. Reexamination was conducted to evaluate the position of the bone graft immediately after the operation and the resorbed capacity of the bone graft before implant restoration. Results The position of the bone graft was consistent with the preoperative design. The amount of bone graft resorbed was within the acceptable range three months after the operation, and the effect of implant restoration was satisfactory. Clinical significance Use of computer-aided design and a 3D-printed template can be an effective approach for accurate bone augmentation in the aesthetic zone of the anterior teeth. |