Durability and Degradation of PVC-P Roofing Membrane—Example of Dynamic Fatigue Testing
Autor: | Andrej Ivanič, Samo Lubej |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | Polymers, Vol 14, Iss 7, p 1312 (2022) |
Druh dokumentu: | article |
ISSN: | 14071312 2073-4360 |
DOI: | 10.3390/polym14071312 |
Popis: | This paper presents a study of PVC-P waterproofing membrane Specimens. The Specimens were taken from different segments of a flat roof after a service life of 11 years. The reason for analysing the condition of the Specimens was the apparent degradation of the waterproofing, which no longer guaranteed the watertightness of the roof. The analysis of the performance of the Specimens was based on the control of the mechanical properties, which were compared with the declared values. The mechanical properties of the degraded PVC-P waterproofing membranes with a polyester mesh backing, which are prescribed by the standards, do not usually deviate from the declared properties. This often poses a problem for liability and warranty claims due to the poor quality of the waterproofing membrane. There may be several causes of degradation of PVC-P. For this reason, in this paper, we present the possibility of controlling the properties of PVC-P waterproofing membranes using cyclic dynamic fatigue, microstructure analysis using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The results show that the cause of the deterioration of the PVC-P waterproofing membranes is often related to dehydrochlorination of the polymer. However, the deterioration of the mechanical properties of the PVC-P waterproofing membranes can be successfully demonstrated by cyclic dynamic fatigue. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |