Autor: |
David Langton, Alvin Ing, Kim Bennetts, Wei Wang, Claude Farah, Matthew Peters, Virginia Plummer, Francis Thien |
Jazyk: |
angličtina |
Rok vydání: |
2018 |
Předmět: |
|
Zdroj: |
BMC Pulmonary Medicine, Vol 18, Iss 1, Pp 1-7 (2018) |
Druh dokumentu: |
article |
ISSN: |
1471-2466 |
DOI: |
10.1186/s12890-018-0721-6 |
Popis: |
Abstract Background In randomized controlled trials, bronchial thermoplasty (BT) has been proven to reduce symptoms in severe asthma, but the mechanisms by which this is achieved are uncertain as most studies have shown no improvement in spirometry. We postulated that BT might improve lung mechanics by altering airway resistance in the small airways of the lung in ways not measured by FEV1. This study aimed to evaluate changes in measures of gas trapping by body plethysmography. Methods A prospective cohort of 32 consecutive patients with severe asthma who were listed for BT at two Australian university hospitals were evaluated at three time points, namely baseline, and then 6 weeks and 6 months post completion of all procedures. At each evaluation, medication usage, symptom scores (Asthma Control Questionnaire, ACQ-5) and exacerbation history were obtained, and lung function was evaluated by (i) spirometry (ii) gas diffusion (KCO) and (iii) static lung volumes by body plethysmography. Results ACQ-5 improved from 3.0 ± 0.8 at baseline to 1.5 ± 0.9 at 6 months (mean ± SD, p |