Severely Damaged Reinforced Concrete Circular Columns Repaired by Turned Steel Rebar and High-Performance Concrete Jacketing with Steel or Polymer Fibers
Autor: | Junqing Xue, Davide Lavorato, Alessandro V. Bergami, Camillo Nuti, Bruno Briseghella, Giuseppe C. Marano, Tao Ji, Ivo Vanzi, Angelo M. Tarantino, Silvia Santini |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2018 |
Předmět: |
seismic behavior
RC structure repair rebar substitution retrofitting high performance fiber reinforced concrete concrete jacket plastic hinge energy dissipation hysteretic damping Technology Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 |
Zdroj: | Applied Sciences, Vol 8, Iss 9, p 1671 (2018) |
Druh dokumentu: | article |
ISSN: | 2076-3417 |
DOI: | 10.3390/app8091671 |
Popis: | A new strategy that repairs severely damaged reinforced concrete (RC) columns after an earthquake is proposed as a simpler and quicker solution with respect to the strategies currently available in the literature. The external concrete parts are removed from the column surface along the whole plastic hinge region to uncover the steel reinforcement. The transverse steel is cut away, and each longitudinal rebar is locally substituted by steel rebar segments connected by welding connections to the original undamaged rebar pieces outside the intervention zone. The new rebar segments have a reduced diameter achieved by turning to ensure plastic deformation only in the plastic hinge, protecting the original rebar and the welding connections. The connection is specifically designed to be effective and simple, and is directly realized on column reinforcement. Finally, the removed concrete is restored by a jacket built with high-performance concrete with steel or polymer fibers. The use of concrete with high volume fraction of polymer fibers to repair the column is investigated for the first time in this paper. This concrete was characterized by compression and flexural tests in the laboratory and its mechanical characteristics were compared with those of the concrete with steel fibers, which are being increasingly used in construction. The repair strategy was applied to two RC columns (1:6 scaled bridge piers), tested by asymmetric cyclic tests. The results show that the column strength, stiffness, and ductility were restored, and the energy dissipation capacity improved. The experimental evidence was investigated by fiber models in OpenSees. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |