Robust and accurate corneal interfaces segmentation in 2D and 3D OCT images

Autor: Xueli Zhu, Wei Huang, Shaodong Ma, Quanyong Yi
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Frontiers in Medicine, Vol 11 (2024)
Druh dokumentu: article
ISSN: 2296-858X
DOI: 10.3389/fmed.2024.1381758
Popis: Segmentation of corneal layer interfaces in optical coherence tomography (OCT) images is important for diagnostic and surgical purposes, while manual segmentation is a time-consuming and tedious process. This paper presents a novel technique for the automatic segmentation of corneal layer interfaces using customized initial layer estimation and a gradient-based segmentation method. The proposed method was also extended to three-dimensional OCT images. Validation was performed on two corneal datasets, one with 37 B-scan images of healthy human eyes and the other with a 3D volume scan of a porcine eye. The approach showed robustness in extracting different layer boundaries in the low-SNR region with lower computational cost but higher accuracy compared to existing techniques. It achieved segmentation errors below 2.1 pixels for both the anterior and posterior layer boundaries in terms of mean unsigned surface positioning error for the first dataset and 2.6 pixels (5.2 μm) for segmenting all three layers that can be resolved in the second dataset. On average, it takes 0.7 and 0.4 seconds to process a cross-sectional B-scan image for datasets one and two, respectively. Our comparative study also showed that it outperforms state-of-the-art methods for quantifying layer interfaces in terms of accuracy and time efficiency.
Databáze: Directory of Open Access Journals