Physiological Responses During High-Intensity Interval Training in Young Swimmers

Autor: Tiago André Freire Almeida, Dalton Müller Pessôa Filho, Mário Cunha Espada, Joana Filipa Reis, Andrei Sancassani, Danilo Alexandre Massini, Fernando Jorge Santos, Francisco Besone Alves
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: Frontiers in Physiology, Vol 12 (2021)
Druh dokumentu: article
ISSN: 1664-042X
DOI: 10.3389/fphys.2021.662029
Popis: This study analyzed whether 100- and 200-m interval training (IT) in swimming differed regarding temporal, perceptual, and physiological responses. The IT was performed at maximal aerobic velocity (MAV) until exhaustion and time spent near to maximalVO2 peak oxygen uptake (⩒O2peak), total time limit (tLim), peak blood lactate [La−] peak, ⩒O2 kinetics (⩒O2K), and rate of perceived exertion (RPE) were compared between protocols. Twelve swimmers (seven males 16.1 ± 1.1 and five females 14.2 ± 1 years) completed a discontinuous incremental step test for the second ventilatory threshold (VT2), ⩒O2peak, and MAV assessment. The swimmers subsequently completed two IT protocols at MAV with 100- and 200-m bouts to determine the maximal ⩒O2 (peak-⩒O2) and time spent ≥VT2, 90, and 95% of ⩒O2peak for the entire protocols (IT100 and IT200) and during the first 800-m of each protocol (IT8x100 and IT4x200). A portable apparatus (K4b2) sampled gas exchange through a snorkel and an underwater led signal controlled the velocity. RPE was also recorded. The Peak-⩒O2 attained during IT8x100 and IT4x200 (57.3 ± 4.9 vs. 57.2 ± 4.6 ml·kg−1·min−1) were not different between protocols (p = 0.98) nor to ⩒O2peak (59.2 ± 4.2 ml·kg−1·min−1, p = 0.37). The time constant of ⩒O2K (24.9 ± 8.4 vs. 25.1 ± 6.3-s, p = 0.67) and [La−] peak (7.9 ± 3.4 and 8.7 ± 1.5 mmol·L−1, p = 0.15) also did not differ between IT100 and IT200. The time spent ≥VT2, 90, and 95%⩒O2peak were also not different between IT8x100 and IT4x200 (p = 0.93, 0.63, and 1.00, respectively). The RPE for IT8x100 was lower than that for IT4x200 (7.62 ± 2 vs. 9.5 ± 0.7, p = 0.01). Both protocols are considered suitable for aerobic power enhancement, since ⩒O2peak was attained with similar ⩒O2K and sustained with no differences in tLim. However, the fact that only the RPE differed between the IT protocols suggested that coaches should consider that nx100-m/15-s is perceived as less difficult to perform compared with nx200-m/30-s for the first 800-m when managing the best strategy to be implemented for aerobic power training.
Databáze: Directory of Open Access Journals