Abstract Aims Pre‐operative or post‐operative heart failure (HF) and cardiogenic shock of various natures frequently remain refractory to conservative treatment and require mechanical circulatory support. We report our clinical experience with large Impella systems (5.0 or 5.5; i.e. Impella 5+) (Abiomed Inc., Boston, USA) and evaluate the parameters that determined patient outcome. Methods and results The initial 50 cases of Impella 5+ implanted for acute HF between November 2018 and August 2020 at a single centre were enrolled in this study. Data, including preoperative characteristics, perioperative clinical course information, and post‐operative outcomes, were retrospectively collected from the hospital data management and quality assurance system. Descriptive and univariate analyses were performed. Among the 49 patients in this study, 28 (56.0%) survived in the first 30 days post‐operatively, and 3 died of non‐cardiac reasons later. In‐hospital mortality was significantly higher in patients with biventricular failure [P |