Effectiveness and Safety of Long Duration versus Short Duration Diode Laser Transscleral Cyclophotocoagulation

Autor: Chan JC, Chow SC, Lai JS
Jazyk: angličtina
Rok vydání: 2020
Předmět:
Zdroj: Clinical Ophthalmology, Vol Volume 14, Pp 197-204 (2020)
Druh dokumentu: article
ISSN: 1177-5483
Popis: Jonathan Cheuk-hung Chan, Shing Chuen Chow, Jimmy Shiu-ming Lai Department of Ophthalmology, University of Hong Kong, Hong KongCorrespondence: Jonathan Cheuk-hung ChanDepartment of Ophthalmology, LKS Faculty of Medicine, University of Hong Kong, Room 301, Block B, Cyberport 4, Hong KongTel +852 3962 1405Email jonnochan@yahoo.comPurpose: To compare the efficacy and safety of diode laser transscleral cyclophotocoagulation using either the long duration or short duration protocol.Methods: Retrospective series of 23 consecutive patients with glaucoma who underwent continuous-wave diode laser transscleral cyclophotocoagulation from August 2016 to July 2018 at a tertiary hospital in Hong Kong. Laser pulse duration for the long and short duration protocols was defined as 3.0– 4.0 and 1.5– 2.0 s, respectively.Results: There were 15 male and 8 female Chinese subjects (23 eyes), age 49– 90 (71.3 ± 2.7), with 10 subjects that underwent long duration cyclophotocoagulation (power 1239.2 ± 78.3 mW, spots 13.9 ± 1.4) and 13 subjects that had short duration cyclophotocoagulation (mean power 1817.3 ± 85.7 mW, spots 14.4 ± 1.0). Six months after long and short duration cyclophotocoagulation, intraocular pressure decreased significantly from 29.9 ± 7.8 to 21.1 ± 6.5 (p < 0.01), and from 35.4 ± 2.7 to 24.1 ± 3.4 (p = 0.04), respectively, while glaucoma medications decreased significantly by 1.4 ± 0.5 (p = 0.02) in the long duration group only. Reduction of medications after short duration cyclophotocoagulation was less and did not reach statistical significance (0.9 ± 0.9, p = 0.15). There was no significant difference of visual deterioration and complication rates.Conclusion: Both types of cyclophotocoagulation were equally effective in lowering intraocular pressure by 6 months, but the short duration protocol, using higher laser power, was able to achieve a greater and earlier reduction, at 3 months. However, the long duration protocol, using less laser power, appears better at reducing medication requirement by 6 months.Keywords: cyclodiode, cycloablation, cyclodestruction, cyclodestructive, g-probe
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje