Popis: |
In-situ metallic glass matrix composites (MGMCs) are a new kind of promising structural engineering material. In this study, a comprehensive study about the corrosion behavior of in-situ Ti46Zr20V12Cu5Be17 MGMCs versus their size was conducted. It is interesting to find that the large sample exhibits a more excellent corrosion resistance than the small sample in the 10% H2SO4 solution both in chemical and electrochemical tests at room temperature. Furthermore, the results obtained from X-ray photoelectron spectra (XPS) demonstrate that the quality of the passive film formed on the large-sized sample is indeed superior to the small-sized sample. Based on (scanning electron microscope) SEM observation, the possible mechanisms of the observed phenomenon have been discussed in the present study. |