Popis: |
Abstract Background Maximal inspiratory pressure (MIP) is currently the most commonly used measure for respiratory muscle strength (RMS) estimation, however, requires significant effort. Falsely low values are therefore common, especially in fatigue-prone subjects, such as neuromuscular disorder patients. In contrast, sniff nasal inspiratory pressure (SNIP) requires a short, sharp sniff; this is a natural manoeuvre, decreasing required effort. Consequently, it has been suggested that use of SNIP could confirm the accuracy of MIP measurements. However, no recent guidelines regarding the optimal method of SNIP measurement exist, and varied approaches have been described. Objectives We compared SNIP values from three conditions, namely with 30, 60 or 90 s time intervals between repeats, the right (SNIPR) and left (SNIPL) nostril, and the contralateral nostril occluded (SNIPO) or non-occluded (SNIPNO). Additionally, we determined the optimal number of repeats for accurate SNIP measurement. Method 52 healthy subjects (23 males) were recruited for this study, of which a subset of 10 subjects (5 males) completed tests comparing the time interval between repeats. SNIP was measured from functional residual capacity via a probe in one nostril, while MIP was measured from residual volume. Results There was no significant difference in SNIP depending on the interval between repeats (P = 0.98); subjects preferred the 30 s. SNIPO was significantly higher than SNIPNO (P |