Risk assessment based on spectrophotometric signals used in eco-friendly analytical scenarios for estimation of carvedilol and hydrochlorothiazide in pharmaceutical formulation

Autor: Mona Nabil, Hoda M. Marzouk, Dina A. Ahmed, Samah S. Abbas, Hayam M. Lotfy
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Scientific Reports, Vol 14, Iss 1, Pp 1-18 (2024)
Druh dokumentu: article
ISSN: 2045-2322
DOI: 10.1038/s41598-024-69746-0
Popis: Abstract Special attention is given to the pharmacological treatment of combined medication of Carvedilol and hydrochlorothiazide which is the most effective and the most beneficial therapy for hypertensive patients with diabetes and various metabolic comorbidities. This work represents spectrophotometric platform scenarios based on factorized spectrum (FS) using interpoint data difference resolution scenarios (IDDRS) coupled with spectrum subtraction method (SS) for the concurrent quantification of carvedilol (CAR) and hydrochlorothiazide (HCT) when present together in a combination without the need for any initial physical separation steps. This IDD resolution scenario based on manipulating the zero-order spectra (D0) of both drugs in the mixture with various spectral features at different wavelength regions (200–400 nm), region I (220–250 nm), region II (240–300 nm) and region III (270–320 nm) via absorbance resolution (AR) and induced absorbance resolution (IAR) methods coupled with corresponding spectrum subtraction (SS). The calibration curves were established across the linearity ranges of 2.0–12.0 µg/mL at 242.50 nm and 4.0–40.0 µg/mL at 285.5 nm for CAR and 1.0–11.0 µg/mL at 226.10 nm and 2.0–20.0 µg/mL at 270.5 nm for HCT. Moreover, methods’ validation was confirmed via ICH guidelines. A Multicenter comparison between sensitivity, specificity in respect resolution sequence were applied using different wavelength regions with various concentration ranges was applied and finally spectral resolution recommendation is issued and cumulative validation score (CVS) is calculated as an indicator in the risk analysis. In quality control laboratories, the studied approaches are applicable for conducting analysis on the mentioned drugs. In addition, the selection of spectrophotometry aligns with the principles of green analytical chemistry, an approach that resonates with the overarching theme of minimizing environmental impact. Via four metric tools named: analytical greenness (AGREE), green analytical procedure index (GAPI), analytical eco-scale, and national environmental method index (NEMI), methods’ greenness profile was guaranteed.
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje