Catheter malposition analysis of totally implantable venous access port in breast cancer patients

Autor: Wenbo Liu, Qingzheng Han, Lin Li, Jiangrui Chi, Xinwei Liu, Yuanting Gu
Jazyk: angličtina
Rok vydání: 2023
Předmět:
Zdroj: Frontiers in Surgery, Vol 9 (2023)
Druh dokumentu: article
ISSN: 2296-875X
DOI: 10.3389/fsurg.2022.1061826
Popis: BackgroundTo investigate the occurrence of catheter malposition in breast cancer patients undergoing Totally Implantable Venous Access Port (TIVAP) implantation and analyze the effect of TIVAP implantation site on the incidence of catheter malposition.MethodsClinical data of Breast cancer patients underwent TIVAP implantation in our department from 2017 to 2021 was collected by reviewing the electronic medical records. The catheter malposition rate, location and management of malposed catheters in TIVAP implantation were analyzed. We divided the patients into the left internal jugular vein (IJV) group and the right IJV group according to the site of TIVAP implantation and compared the difference in the catheter malposition incidence between the two groups. In addition, we counted the catheter malposition rate of TIVAP implantion via the left and right IJV in right breast cancer patients to analyze the effect of tumor status on the side of TIVAP implantation on the catheter malposition rate.ResultsA total of 1,510 catheters were implanted in 1,504 patients, and 16 (1.06%) had catheter malposition. The catheter malposition rate was 4.96% (7/141) for TIVAP implanted via the left IJV and 0.66% (9/1,369) for right IJV, with a statistically significant difference (χ2 = 18.699, P