Calculation of protection function settings of new elements of the 500 kV transmission system
Autor: | Sučević Nikola |
---|---|
Jazyk: | English<br />Serbian |
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | Zbornik Radova: Elektrotehnički Institut "Nikola Tesla", Vol 2022, Iss 32, Pp 15-25 (2022) |
Druh dokumentu: | article |
ISSN: | 0350-8528 2406-1212 |
DOI: | 10.5937/zeint32-41337 |
Popis: | In the paper the protection function setting calculations for elements of the transmission system are shown. Analyzed transmission system consists of the 500 kV and 230 kV voltage levels. The setting calculations are shown for several protection functions for the 500 kV reactors, 500/230 kV/kV autotransformers and 500 kV line. Network modeling and analysis have been performed using DIgSILENT PowerFactory. |