Comparative evaluation of three classical sizing methods of vibrating screens
Autor: | Cristiano Geraldo Sales, Roberto Galery |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: | |
Zdroj: | REM: International Engineering Journal, Vol 75, Iss 1, Pp 37-44 (2021) |
Druh dokumentu: | article |
ISSN: | 2448-167X 0370-4467 |
DOI: | 10.1590/0370-44672019750169 |
Popis: | Abstract The sizing of vibrating screen machines can be done by various methods, most of them based on the classic method of Allis Chalmers (ACM). Due to the wide diffusion and applicability, the Peter King (PKM) and Karra (KM) methods present great technical relevance as well. The objective of this study was to evaluate and compare the results of the screen surface areas, calculated by these three methods, and the real areas of the industrial machines. The study was based on data generated in 11 real industrial screening operations, being possible to evaluate the deviations of the areas calculated by the mathematical methods in relation to the real areas of the industrial machines. Results have shown that although all methods have restrictions on their use, PKM has the smallest deviations compared to the real dimensions of the industrial machines for four screening conditions. All these conditions showed screen apertures from 4.76mm to 19mm, moisture from 2.12% to 3.3%, Gneiss as feed material and deviations smaller than 13%. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |