Popis: |
Background: Oral hypoglycemic agents are a frequent cause of hypoglycemia in nondiabetic people. Here, we report a case of recurrent hypoglycemia caused by glipizide, in which diagnosis was delayed because of a combination of delayed hypoglycemic agent screening and low sensitivity of the hypoglycemic agent screening panel used. Case Report: A 66-year-old woman repeatedly presented with symptomatic hypoglycemia. At the first presentation, the serum glucose level was 40 mg/dL (2.2 mmol/L), C-peptide level was 13.1 ng/mL (0.8-3.1 ng/mL), proinsulin level was 96.9 pmol/L ( |