Suture Tape–Reinforced Human Dermal Allograft Used for Superior Capsule Reconstruction Demonstrates Improved Ability to Withstand Elongation

Autor: Cody S. Lee, M.D., Manoj Reddy, M.D., Bryan Scott, M.D., Daniel Curtis, M.D., Farid Amirouche, Ph.D., Aravind Athiviraham, M.D.
Jazyk: angličtina
Rok vydání: 2020
Předmět:
Zdroj: Arthroscopy, Sports Medicine, and Rehabilitation, Vol 2, Iss 5, Pp e511-e515 (2020)
Druh dokumentu: article
ISSN: 2666-061X
DOI: 10.1016/j.asmr.2020.05.015
Popis: Purpose: To investigate the potential for a suture tape–reinforcement technique to prevent elongation with repetitive use of a human dermal (HD) allograft traditionally used for superior capsule reconstruction in a biomechanical model. Methods: Using 8 scapulae and humeri Sawbones models, the standard superior capsule reconstruction was performed using 8 HD allografts. Four grafts were tested in the native state, whereas 4 were tested using reinforcement. Allografts were reinforced using suture tape in a running 360° fashion around the allograft borders, maintaining 5 mm of space from the edges. Allografts were measured pre- and postdynamic testing for length, width, and thickness. All specimens were affixed to a materials testing machine that allowed for allograft orientation in a longitudinal plane throughout testing. Specimens were preloaded to 10 N and then cyclically loaded to 100 N at a rate of 15 mm/s for 30 cycles. Results: After dynamic, cyclic loading, suture tape–reinforced allografts experienced a significantly smaller percent change in anterior length (6.36% vs 14.50%, P = .013), posterior length (6.00% vs 13.68%, P = .002), medial width (5.80% vs 21.05%, P = .001), lateral width (5.45% vs 19.29%, P < .001), medial thickness (4.38% vs 17.93%, P = .005), central thickness (7.03% vs 16.11%, P = .026), and lateral thickness (4.55% vs 20.80%, P < .001). Linear stiffness values obtained for suture tape –reinforced allografts were significantly greater than those for native allografts when measured at cycles 1 (21.18 ± 1.03 N/mm vs 17.69 ± 1.91 N/mm, P = .02), 15 (29.90 ± 1.45 vs 24.93 ± 2.79, P = .03), and 30 (32.13 ± 1.98 N/mm vs 25.72 ± 3.01 N/mm, P = .01) of dynamic testing Conclusions: The suture tape–reinforcement technique described decreased HD allograft elongation, maintained graft thickness, and improved linear stiffness values following uniplanar cyclic loading in a biomechanical Sawbones model. Clinical relevance: Suture tape reinforcement of the HD allograft could serve as one strategy to overcome the issue of allograft elongation with time following superior capsule reconstruction.
Databáze: Directory of Open Access Journals