Transcatheter Edge-to-Edge Repair of the Mitral Valve in Four Dogs: Preliminary Results Regarding Efficacy and Safety

Autor: Soontaree Petchdee, Wanpitak Pongkan, Jing Lei, Kotchapol Jaturanratsamee, Ratikorn Bootcha, Wannisa Meepoo, Chattida Panprom
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Animals, Vol 14, Iss 21, p 3068 (2024)
Druh dokumentu: article
ISSN: 2076-2615
DOI: 10.3390/ani14213068
Popis: Mitral valve disease is a common heart disease in dogs. The aim of this study was to describe the cases of dogs that underwent mitral valve repair via a V-clamp device and to provide long-term follow-up data on cardiac function after mitral valve repair. Four dogs with mitral valve regurgitation who experienced coughing and dyspnea underwent surgical mitral valve repair between December 2023 and March 2024. The patients were evaluated via transthoracic and transesophageal echocardiography. Echocardiography revealed mitral valve leaflet regurgitation. Mitral valve repair was performed under general anesthesia using a V-clamp device introduced through an introducer wire guide. Echocardiography was conducted at baseline and during the six-month follow-up. Blood analysis results after surgical repair were normal. Follow-up echocardiography revealed no complications related to the procedure, with all dogs demonstrating improved respiratory signs and quality of life after repair. No adverse reactions were reported after surgery. A V-clamp device was used to repair mitral valve regurgitation in four dogs. Mitral valve repair via a V-clamp device is another treatment option for mitral valve disease in dogs.