Spleen Stiffness on Magnetic Resonance Elastography for the Detection of Portal Hypertension: A Systematic Review and Meta-Analysis

Autor: Ma Yiyi, Qian Xiaoqin, Zhang Lei
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Iranian Journal of Public Health, Vol 51, Iss 9 (2022)
Druh dokumentu: article
ISSN: 2251-6085
2251-6093
DOI: 10.18502/ijph.v51i9.10548
Popis: Background: Chronic liver disease, complicated by portal hypertension (PH), may alter the extra-hepatic hemodynamic condition and spleen stiffness (SS). We aimed to evaluate the diagnostic accuracy of MRI-based elastographic methods (MRE) for detecting PH. Methods: Seven studies were included with reference to SS with regard to the prediction of PH patients. Major outcomes considered for data extraction were diagnostic parameters for MRI for concluding mild PH, clinically significant PH and severe PH. PubMed, Scopus, Google Scholar, Cochrane and Science Direct databases were used to extract the published literature through to May, 2021Using the Rayyan Zotero and R softwares Results: Out of 587 studies extracted, 7 were selected based on inclusion and exclusion criteria. A QUADAS-2 assessment showed that all studies were clear in terms of patient selection and reference standard. A funnel plot showed that all the selected studies were outliers, indicating a low level of accuracy for the studies included. Subgroup analysis, with reference to SS as a predictor of PH, revealed raw mean difference (RMD) of 7.78% (95% CI 5.23-10.34, P60 yr were 34.26% (95% CI 9.33- 59.20, I2=100%,
Databáze: Directory of Open Access Journals