Popis: |
The detection of dopamine is of great significance for human health. Herein, Pd nanoparticles were loaded on Cu nanoplates (Pd/Cu NPTs) by a novel liquid phase reduction method. A novel dopamine (DA) electrochemical sensor based on the Pd NPs/Cu/glass carbon electrode (Pd/Cu NPTs/GCE) was constructed. This sensor showed a wide linear range of 0.047 mM to 1.122 mM and a low limit of detection (LOD) of 0.1045 μM (S/N = 3) for DA. The improved performance of this sensor is attributed to the obtained tiny Pd nanoparticles which increase the catalytic active sites and electrochemical active surface areas (ECSAs). Moreover, the larger surface area of two–dimensional Cu nanoplates can load more Pd nanoparticles, which is another reason to improve performance. The Pd/Cu NPTs/GCE sensor also showed a good reproducibility, stability, and excellent anti–interference ability. |