Determination of Pressure Coefficient for a High-Rise Building with Atypical Ground Plan
Autor: | Medvecká Soňa, Ivánková Ol’ga, Macák Marek, Michalcová Vladimíra |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2018 |
Předmět: | |
Zdroj: | Civil and Environmental Engineering, Vol 14, Iss 2, Pp 138-145 (2018) |
Druh dokumentu: | article |
ISSN: | 1336-5835 2199-6512 |
DOI: | 10.2478/cee-2018-0018 |
Popis: | In this article, the results of pressure coefficient on the atypical object obtained by experimental measurements in a boundary layer wind tunnel (BLWT) of Slovak University of Technology in Bratislava (STU) and computational fluid dynamics simulation (CFD) are presented. The pressure coefficient is one of the most important parameters expressing the wind pressure distribution on the structure. The loading by wind can only be acquired by execution of detailed tests and numerical analyses [1]. |
Databáze: | Directory of Open Access Journals |