Using a Pair of Different-Sized Spheres to Calibrate Radar Data in the Microwave Anechoic Chamber

Autor: Jiangkun Gong, Jun Yan, Deren Li, Huiping Hu, Deyong Kong
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Applied Sciences, Vol 12, Iss 17, p 8901 (2022)
Druh dokumentu: article
ISSN: 2076-3417
DOI: 10.3390/app12178901
Popis: Traditional radar calibration methods often use one standard sphere as the standard calibration object, but researchers seldom discuss the size and the material content of the calibration sphere. We propose using a pair of different-sized spheres to verify the standard method. In a microwave anechoic chamber, the simulated and measured results show that the radar cross-section (RCS) values of two spheres with radii of 0.15 m and 0.05 m in the Mie region differ from their physical cross-sections in the optic region, and only in the optic region, their difference of RCS value (i.e., 9.5424 dB) can be approximately equal to the theoretical one (i.e., 9.6803 dB). Thus, radar calibration should be conducted in the same scattering region for both the calibration object and the calibrated target. The use of two different-sized spheres can aid in three applications: (1) verifying the scattering regions, (2) searching the pure area in the microwave anechoic chamber, and (3) locating the positions of the targets in the range profiles.
Databáze: Directory of Open Access Journals