Autor: |
Stefan Seeger, Thomas Ruckstuhl, Christian M. Winterflood |
Jazyk: |
angličtina |
Rok vydání: |
2013 |
Předmět: |
|
Zdroj: |
Biosensors, Vol 3, Iss 1, Pp 108-115 (2013) |
Druh dokumentu: |
article |
ISSN: |
2079-6374 |
DOI: |
10.3390/bios3010108 |
Popis: |
We present an immunoassay for Interferon-γ (IFN-γ) with a limit of detection of 1.9 pM (30 pg/mL) and a linear concentration range spanning three orders of magnitude. The developed one-step assay takes only 12 min and can replace the time-consuming and labor-intensive enzyme-linked immunosorbent assay (ELISA). The solid-phase sandwich assay is performed on a new measurement system comprising single-use test tubes and a compact fluorescence reader. The polymer tubes contain an optical configuration for the detection of supercritical angle fluorescence, allowing for highly sensitive real-time binding measurements. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|