Popis: |
The control strategy of the gas supply subsystem is very important to ensure the performance and stability of the fuel cell system. However, due to the inherent nonlinear characteristics of the fuel cell gas supply subsystem, the traditional control strategy is mainly based on proportional integral (PI) control, which has the disadvantages of large limitation, large error, limited immunity, and inconsistent control performance, which seriously affects its effectiveness. In order to overcome these challenges, this paper proposes an optimal control method for air supply subsystems based on nonlinear active disturbance rejection control (ADRC). Firstly, a seven-order fuel cell system model is established, and then, the nonlinear ADRC and traditional PI control strategies are compared and analyzed. Finally, the two strategies are simulated and compared. The validation results indicate that the integral absolute error (IAE) measure of PI control is 0.502, the integral square error (ISE) measure is 0.1382, and the total variation (TV) measure is 399.1248. Compared with the PI control, the IAE and ISE indexes of ADRC were reduced by 61.31% and 58.03%, respectively. ADRC is superior to PI control strategy in all aspects and realizes the efficient adjustment of the system under different working conditions. ADRC is more suitable for the nonlinear characteristics of the gas supply system and is more suitable for the oxygen excess ratio (OER). |