Autor: |
Nicole Ferreira Silvério, MSc, Wouter van den Wollenberg, PhD, Anja Betgen, MSc, Lisa Wiersema, BSc, Corrie Marijnen, Prof. Dr., Femke Peters, MD, PhD, Uulke A. van der Heide, Prof. Dr., Rita Simões, PhD, Tomas Janssen, PhD |
Jazyk: |
angličtina |
Rok vydání: |
2024 |
Předmět: |
|
Zdroj: |
Advances in Radiation Oncology, Vol 9, Iss 6, Pp 101483- (2024) |
Druh dokumentu: |
article |
ISSN: |
2452-1094 |
DOI: |
10.1016/j.adro.2024.101483 |
Popis: |
Purpose: Segmentation of clinical target volumes (CTV) on medical images can be time-consuming and is prone to interobserver variation (IOV). This is a problem for online adaptive radiation therapy, where CTV segmentation must be performed every treatment fraction, leading to longer treatment times and logistic challenges. Deep learning (DL)-based auto-contouring has the potential to speed up CTV contouring, but its current clinical use is limited. One reason for this is that it can be time-consuming to verify the accuracy of CTV contours produced using auto-contouring, and there is a risk of bias being introduced. To be accepted by clinicians, auto-contouring must be trustworthy. Therefore, there is a need for a comprehensive commissioning framework when introducing DL-based auto-contouring in clinical practice. We present such a framework and apply it to an in-house developed DL model for auto-contouring of the CTV in rectal cancer patients treated with MRI-guided online adaptive radiation therapy. Methods and Materials: The framework for evaluating DL-based auto-contouring consisted of 3 steps: (1) Quantitative evaluation of the model's performance and comparison with IOV; (2) Expert observations and corrections; and (3) Evaluation of the impact on expected volumetric target coverage. These steps were performed on independent data sets. The framework was applied to an in-house trained nnU-Net model, using the data of 44 rectal cancer patients treated at our institution. Results: The framework established that the model's performance after expert corrections was comparable to IOV, and although the model introduced a bias, this had no relevant impact on clinical practice. Additionally, we found a substantial time gain without reducing quality as determined by volumetric target coverage. Conclusions: Our framework provides a comprehensive evaluation of the performance and clinical usability of target auto-contouring models. Based on the results, we conclude that the model is eligible for clinical use. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|