Comparison of Raman and Mid-Infrared Spectroscopy for Real-Time Monitoring of Yeast Fermentations: A Proof-of-Concept for Multi-Channel Photometric Sensors
Autor: | Robert Schalk, Annabell Heintz, Frank Braun, Giuseppe Iacono, Matthias Rädle, Norbert Gretz, Frank-Jürgen Methner, Thomas Beuermann |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
Raman spectroscopy
mid-infrared spectroscopy fermentation of Saccharomyces cerevisiae real-time monitoring multi-channel photometric sensors multiple linear regression partial least squares regression monitoring of glucose ethanol biomass Technology Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 |
Zdroj: | Applied Sciences, Vol 9, Iss 12, p 2472 (2019) |
Druh dokumentu: | article |
ISSN: | 2076-3417 |
DOI: | 10.3390/app9122472 |
Popis: | Raman and mid-infrared (MIR) spectroscopy are useful tools for the specific detection of molecules, since both methods are based on the excitation of fundamental vibration modes. In this study, Raman and MIR spectroscopy were applied simultaneously during aerobic yeast fermentations of Saccharomyces cerevisiae. Based on the recorded Raman intensities and MIR absorption spectra, respectively, temporal concentration courses of glucose, ethanol, and biomass were determined. The chemometric methods used to evaluate the analyte concentrations were partial least squares (PLS) regression and multiple linear regression (MLR). In view of potential photometric sensors, MLR models based on two (2D) and four (4D) analyte-specific optical channels were developed. All chemometric models were tested to predict glucose concentrations between 0 and 30 g L−1, ethanol concentrations between 0 and 10 g L−1, and biomass concentrations up to 15 g L−1 in real time during diauxic growth. Root-mean-squared errors of prediction (RMSEP) of 0.68 g L−1, 0.48 g L−1, and 0.37 g L−1 for glucose, ethanol, and biomass were achieved using the MIR setup combined with a PLS model. In the case of Raman spectroscopy, the corresponding RMSEP values were 0.92 g L−1, 0.39 g L−1, and 0.29 g L−1. Nevertheless, the simple 4D MLR models could reach the performance of the more complex PLS evaluation. Consequently, the replacement of spectrometer setups by four-channel sensors were discussed. Moreover, the advantages and disadvantages of Raman and MIR setups are demonstrated with regard to process implementation. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |