Autor: |
Lauren Gummery, Saloum Jallow, Alexandra G Raftery, Euan Bennet, Jean Rodgers, David G M Sutton |
Jazyk: |
angličtina |
Rok vydání: |
2020 |
Předmět: |
|
Zdroj: |
PLoS ONE, Vol 15, Iss 8, p e0237187 (2020) |
Druh dokumentu: |
article |
ISSN: |
1932-6203 |
DOI: |
10.1371/journal.pone.0237187 |
Popis: |
IntroductionInfection of equids with Trypanosoma brucei (T. brucei) ssp. is of socioeconomic importance across sub-Saharan Africa as the disease often progresses to cause fatal meningoencephalitis. Loop-mediated isothermal amplification (LAMP) has been developed as a cost-effective molecular diagnostic test and is potentially applicable for use in field-based laboratories.Part iThreshold levels for T. brucei ssp. detection by LAMP were determined using whole equine blood specimens spiked with known concentrations of parasites. Results were compared to OIE antemortem gold standard of T. brucei-PCR (TBR-PCR).Results iThreshold for detection of T. brucei ssp. on extracted DNA from whole blood was 1 parasite/ml blood for LAMP and TBR-PCR, and there was excellent agreement (14/15) between tests at high (1 x 103/ml) concentrations of parasites. Detection threshold was 100 parasites/ml using LAMP on whole blood (LWB). Threshold for LWB improved to 10 parasites/ml with detergent included. Performance was excellent for LAMP at high (1 x 103/ml) concentrations of parasites (15/15, 100%) but was variable at lower concentrations. Agreement between tests was weak to moderate, with the highest for TBR-PCR and LAMP on DNA extracted from whole blood (Cohen's kappa 0.95, 95% CI 0.64-1.00).Part iiA prospective cross-sectional study of working equids meeting clinical criteria for trypanosomiasis was undertaken in The Gambia. LAMP was evaluated against subsequent TBR-PCR.Results iiWhole blood samples from 321 equids in The Gambia were processed under field conditions. There was weak agreement between LWB and TBR-PCR (Cohen's kappa 0.34, 95% CI 0.19-0.49) but excellent agreement when testing CSF (100% agreement on 6 samples).ConclusionsFindings support that LAMP is comparable to PCR when used on CSF samples in the field, an important tool for clinical decision making. Results suggest repeatability is low in animals with low parasitaemia. Negative samples should be interpreted in the context of clinical presentation. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|