Autor: |
Haisong Liu, PhD, Evan M. Thomas, MD, PhD, Jun Li, PhD, Yan Yu, PhD, David Andrews, MD, James M. Markert, MD, John B. Fiveash, MD, Wenyin Shi, MD, PhD, Richard A. Popple, PhD |
Jazyk: |
angličtina |
Rok vydání: |
2020 |
Předmět: |
|
Zdroj: |
Advances in Radiation Oncology, Vol 5, Iss 5, Pp 1051-1060 (2020) |
Druh dokumentu: |
article |
ISSN: |
2452-1094 |
DOI: |
10.1016/j.adro.2019.10.007 |
Popis: |
Purpose: Interest and application of stereotactic radiosurgery for multiple brain metastases continue to increase. Various planning systems are available for linear accelerator (linac)–based single-isocenter multiple metastasis radiosurgery. Two of the most advanced systems are BrainLAB Multiple Metastases Elements (MME), a dynamic conformal arc (DCA) approach, and Varian RapidArc (RA), a volumetric modulated arc therapy (VMAT) approach. In this work, we systematically compared plan quality between the 2 techniques. Methods and Materials: Thirty patients with 4 to 10 metastases (217 total; median 7.5; Vmin = 0.014 cm3; Vmax = 17.73 cm3) were planned with both Varian RA and MME at 2 different institutions with extensive experience in each respective technique. All plans had a single isocenter and used Varian linac equipped with high-definition multileaf collimator. RA plans used 2 to 4 noncoplanar VMAT arcs with 10 MV flattening filter-free beam. MME plans used 4 to 9 noncoplanar DCAs and 6 MV flattening filter-free beam, (minimum planning target volume [PTVmin] = 0.49 cm3; PTVmax = 27.32 cm3; PTVmedian = 7.05 cm3). Prescriptions were 14 to 24 Gy in a single fraction. Target coverage goal was 99% of volume receiving prescription dose (D99% ≥ 100%). Plans were evaluated by Radiation Therapy Oncology Group/Paddick conformity index (CI) score, 12 Gy volume (V12Gy), V8Gy, V5Gy, mean brain dose (Dmean), and beam-on time. Results: Conformity was favorable among RA plans (median: MME CIRTOG = 1.38; RA CIRTOG = 1.21; P < .0001). V12Gy and V8Gy were lower for RA plans (median: MME V12 = 23.7 cm3; RA V12 = 19.2 cm3; P = .0001; median: MME V8Gy = 53.6 cm3; RA V8Gy = 44.1 cm3; P = .024). V5Gy was lower for MME plans (median: MME V5Gy = 141.4 cm3; RA V5Gy = 142.8 cm3; P = .009). Mean brain was lower for MME plans (median: MME Dmean = 2.57 Gy; RA Dmean = 2.76 Gy; P < .0001). Conclusions: For linac-based multiple metastasis stereotactic radiosurgery, RapidArc VMAT facilitates favorable conformity and V12Gy/V8Gy volume compared with the MME DCA plan. MME planning facilitates reduced dose spill at levels ≤V5Gy. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|