Revisiting the Diagnostic Performance of the Modified Nine-Step Test for Obstructive and Patulous Eustachian Tube Dysfunction

Autor: Seong Hoon Bae, Seojin Moon, Mincheol Jeong, In Seok Moon
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Diagnostics, Vol 12, Iss 3, p 732 (2022)
Druh dokumentu: article
ISSN: 12030732
2075-4418
DOI: 10.3390/diagnostics12030732
Popis: The nine-step test is a classical method for evaluating Eustachian tube function. It directly assesses the patient’s capacity to equilibrate middle ear pressure by swallowing. However, there are insufficient studies to appraise its diagnostic performance. The purpose of this study is to evaluate the sensitivity, specificity, and cut-off value of the nine-step test in patients with obstructive Eustachian tube dysfunction (oETD) and patulous Eustachian tube (PET). Enrolled subjects were divided into three groups. Control (50 ears of healthy volunteers), oETD (19 ears with oETD), and PET (29 ears with PET). Receiver operating characteristics curve analysis was conducted to evaluate the diagnostic performance of maximal peak pressure difference (ETTmd) in the nine-step test. Both the oETD group and the PET group showed decreased ETTmd. The nine-step test showed moderate accuracy when used to diagnose oETD (area under the curve = 0.875) and PET (area under the curve = 0.769). The highest diagnostic performance was observed when the cut-off value was 13 daPa for both the oETD group (sensitivity = 73.7%, specificity = 90.0%) and the PET group (sensitivity = 58.6%, specificity = 90.0%). The nine-step test has moderate diagnostic performance for oETD and PET.
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje