Popis: Recurrence of anterior instability after a Latarjet procedure with persistent glenoid bone loss can be related to coracoid bone block resorption, migration, or malposition. Multiple options are available to address anterior glenoid bone loss, including autograft bone transfers (such as iliac crest graft, distal clavicle autograft) or allografts (distal tibia allograft). Here, we present the use of the remnant coracoid process as an option for consideration in the treatment of glenoid bone loss after failed Latarjet procedure with persistent glenoid bone loss. The remnant coracoid autograft is harvested and transferred inside the glenohumeral joint, through the rotator interval, and fixed using cortical buttons. This arthroscopic procedure includes using 1) glenoid and coracoid drilling guides to optimize graft positioning and making the procedure more reproducible and safer and 2) a suture tensioning device to provide intraoperative graft compression and ensure bone graft healing.