Clinical safety and efficacy of a preloaded monofocal hydrophobic acrylic intraocular lens in a real-world population

Autor: Samuel Giles Latham, Francis Carr, Hala Ali, Vinod Gangwani
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: BMC Ophthalmology, Vol 21, Iss 1, Pp 1-7 (2021)
Druh dokumentu: article
ISSN: 1471-2415
DOI: 10.1186/s12886-021-02142-8
Popis: Abstract Background This study was designed to evaluate visual, refractive and safety outcomes in eyes after they underwent phacoemulsification and implantation of a preloaded monofocal hydrophobic acrylic intraocular lens. Methods This was a single center observational study conducted at Ashford and St Peter’s Hospitals NHS Foundation Trust, United Kingdom. Patients were included if they had cataract extraction with in-the-bag implantation of the EyeCee® One preloaded intraocular lens from August to October 2019. Pre-operative, surgery-related and 2 weeks and 3 months post-operative data was collected. Surgeons at this trust were then asked to complete a feedback form to evaluate their experience of implanting the EyeCee® One. Results One hundred fifty-two eyes were included in the study. Ninety-four (62%) of these eyes had cataract but no concomitant ocular pathology that could potentially affect visual acuity. Three months post-operatively, 98.7% of all eyes had monocular CDVA ≤0.3 logMAR. 100% of the eyes without concomitant ocular pathology achieved this target. The mean CDVA of all eyes in this study improved from 0.43 ± 0.43 logMAR pre-operatively, to 0.05 ± 0.11 logMAR post-operatively (p
Databáze: Directory of Open Access Journals