Optimizing gentamicin conventional and extended interval dosing in neonates using Monte Carlo simulation – a retrospective study

Autor: Monique Bergenwall, Sandra A. N. Walker, Marion Elligsen, Dolores C. Iaboni, Carla Findlater, Winnie Seto, Eugene Ng
Jazyk: angličtina
Rok vydání: 2019
Předmět:
Zdroj: BMC Pediatrics, Vol 19, Iss 1, Pp 1-13 (2019)
Druh dokumentu: article
ISSN: 1471-2431
DOI: 10.1186/s12887-019-1676-3
Popis: Abstract Background Although aminoglycosides are routinely used in neonates, controversy exists regarding empiric dosing regimens. The objectives were to determine gentamicin pharmacokinetics in neonates, and develop initial mg/kg dosing recommendations that optimized target peak and trough concentration attainment for conventional and extended-interval dosing (EID) regimens. Methods Patient demographics and steady-state gentamicin concentration data were retrospectively collected for 60 neonates with no renal impairment admitted to a level III neonatal intensive care unit. Mean pharmacokinetics were calculated and multiple linear regression was performed to determine significant covariates of clearance (L/h) and volume of distribution (L). Classification and regression tree (CART) analysis identified breakpoints for significant covariates. Monte Carlo Simulation (MCS) was used to determine optimal dosing recommendations for each CART-identified sub-group. Results Gentamicin clearance and volume of distribution were significantly associated with weight at gentamicin initiation. CART-identified breakpoints for weight at gentamicin initiation were: ≤ 850 g, 851-1200 g, and > 1200 g. MCS identified that a conventional dose of gentamicin 3.5 mg/kg given every 48 h or an EID of 8-9 mg/kg administered every 72 h in neonates weighing ≤ 850 g, and every 24 and 48 h, respectively, in neonates weighing 851-1200 g, provided the best probability of attaining conventional (peak: 5-10 mg/L and trough: ≤ 2 mg/L) and EID targets (peak:12-20 mg/L, trough:≤ 0.5 mg/L). Insufficient sample size in the > 1200 g neonatal group precluded further investigation of this weight category. Conclusions This study provides initial gentamicin dosing recommendations that optimize target attainment for conventional and EID regimens in neonates weighing ≤ 1200 g. Prospective validation and empiric dose optimization for neonates > 1200 g is needed.
Databáze: Directory of Open Access Journals