Micro-dose Paranasal Computed Tomography is Valuable When Evaluating Diseases of the Paranasal Sinuses

Autor: Mustafa Özbayrak, Burak Ertaş, Özden Sila Ulus, Alper Özdilek, Ercan Karaarslan
Jazyk: English<br />Turkish
Rok vydání: 2019
Předmět:
Zdroj: Haseki Tıp Bülteni, Vol 57, Iss 2, Pp 142-146 (2019)
Druh dokumentu: article
ISSN: 1302-0072
2147-2688
DOI: 10.4274/haseki.galenos.2018.4594
Popis: Aim:We explored whether a reduction in the radiation dose affected the quality of diagnostic images generated using third-generation dual-source computed tomography (CT) running advanced third-generation iterative reconstruction software.Methods:From February to May 2015, 72 consecutive patients aged 16 to 64 years with clinically suspected sinusitis were randomly and prospectively enrolled and divided into two groups (standard or micro-dose CT). Anatomical landmarks and mucosal structures were independently evaluated by a radiologist and an otorhinolaryngologist using a four-point grading scale. Mean scores were calculated and compared.Results:All images were of diagnostic quality. The mean effective radiation dose was significantly lower in patients evaluated via the micro-dose protocol (group 2) than in those evaluated using the standard protocol (group 1) (p0.05).Conclusion:The radiation dose to the paranasal sinus delivered during CT in patients with suspected sinusitis can be reduced to 0.003 mSv using third-generation dual-source CT running advanced iterative reconstruction software.
Databáze: Directory of Open Access Journals