A novel individual reconstruction of a medial orbital wall blow-out fracture using a bone graft molded intraoperatively using a 3-D model: a case report

Autor: P.J. Meier, MBBS, C. Jadhav, MBBS, D.A. Morrison, PhD, A.J. Hayes, B.Eng S, S. Cunneen, MBBS, FRACS
Jazyk: angličtina
Rok vydání: 2016
Předmět:
Zdroj: Oral and Maxillofacial Surgery Cases, Vol 2, Iss 2, Pp 19-21 (2016)
Druh dokumentu: article
ISSN: 2214-5419
DOI: 10.1016/j.omsc.2016.05.001
Popis: This report describes the surgical reconstruction of a traumatic medial orbital wall blow-out fracture using an autologous calvarial bone graft modeled intraoperatively using a three-dimensional (3-D) fused deposition model of the fracture defect. Previous case reports have demonstrated the use of 3-D models in planning the surgical approach, selecting and fashioning the desired implant in the perioperative period, and even using models with sterile coverings intraoperatively to mold synthetic implants. This is an individually unique application of 3-D printing for the surgical repair of pure medical wall blow-out fracture.