Parameter optimization method for delamination defects detection of composite laminate using phased array ultrasonic

Autor: CAO Hong-yi, JIANG Ming-shun, MA Meng-yuan, ZHANG Fa-ye, ZHANG Lei, SUI Qing-mei, JIA Lei
Jazyk: čínština
Rok vydání: 2020
Předmět:
Zdroj: Cailiao gongcheng, Vol 48, Iss 9, Pp 158-165 (2020)
Druh dokumentu: article
ISSN: 1001-4381
DOI: 10.11868/j.issn.1001-4381.2019.000777
Popis: Aiming at the problem of accurate identification of delamination defects of composite laminates, an optimization method of activation aperture of phased array ultrasonic testing was proposed by simulation and experiment, and the effects of the activation aperture on the acoustic field characteristics and detection results at different focusing depths were studied and analyzed. Firstly, for the phase array ultrasonic contact testing method, the multipoint source 3D acoustic field model under the solid-solid interface was deduced. Then, the phase array ultrasonic sound field was simulated, and the characteristics of sound field under different activation apertures were analyzed. Finally, the carbon fiber reinforced polymer (CFRP) laminate with delamination defects was prepared using autoclave process, and a phased array ultrasonic testing system was built to test the CFRP laminate test block. The experimental results show that the accurate identification of CFRP lamination defects can be achieved by optimizing the activation aperture of phased array ultrasound, and the defect detection accuracy can be improved effectively.