Optimal determination of valve setting coefficient for the multi-tank water feeder system
Autor: | Boopathi Ramakrishnan, G. Madhavi Ganesan |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2024 |
Předmět: | |
Zdroj: | Water Supply, Vol 24, Iss 5, Pp 1912-1923 (2024) |
Druh dokumentu: | article |
ISSN: | 1606-9749 1607-0798 |
DOI: | 10.2166/ws.2024.105 |
Popis: | Filling up water to several water distribution service tanks equitably needs a proper valve setting in the operation. Setting by trial and error requires considerable time which could invite more labour-level exercise. This study addresses the issue of unequal water distribution to elevated service tanks (ESTs). It is possible to achieve an optimal valve loss coefficient, which ensures equal water supply to all ESTs. Throttle and control valves play a crucial role in regulating the flow rate and pressure of water. An optimization framework for the valve setting coefficient is proposed. The genetic algorithm is used as an optimization model and hydraulic simulation is performed using EPANET 2.0 software through its toolkits. The proposed model is applied to a hypothetical system and illustrated. The obtained valve setting coefficients make equitable distribution of water to all the ESTs. HIGHLIGHTS To fill the water to multiple elevated service tanks in real-time a lot of effort is required. This research addresses this problem.; Using GA, EPANET toolkit and Python code optimization has been made to set the most optimum valve coefficient.; It has been checked for small networks and bigger networks with more tanks and good results were obtained.; It will save water.; Consumers will be satisfied.; |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |