Avaliação em escala laboratorial da utilização do processo eletrolítico no tratamento de águas Laboratory scale assessment of an electrolytic process for water treatment
Autor: | Marcelo Henrique Otenio, Luciana Cadioli Panchoni, Gabriela Correia Araújo da Cruz, Clézio Ravanhani, Ederio Dino Bidóia |
---|---|
Jazyk: | English<br />Spanish; Castilian<br />Portuguese |
Rok vydání: | 2008 |
Předmět: | |
Zdroj: | Química Nova, Vol 31, Iss 3, Pp 508-513 (2008) |
Druh dokumentu: | article |
ISSN: | 0100-4042 1678-7064 |
DOI: | 10.1590/S0100-40422008000300008 |
Popis: | Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |